Model | 3TS-210 | ||||
Internal dimensions(mm) | 500*500*400 | 700*600*500 | 700*780*550 | 900*800*700 | |
Overall dimensions(mm) | 1150*1950*2100 | 1350*2100*2200 | 1350*2250*2300 | 2500*2250*2150 | |
Sample Loads | 10kg | 15kg | 25kg | 35kg | |
Pre-heat room
| Upper limit preheat temperature | +220℃ | |||
Heating time | Ambient temperature to ~ + 200℃, within in 30 minutes. | ||||
Pre-cool room | Lower limit pre-cool temperature | -70℃ | |||
Cooling time | Ambient temperature to ~ -70℃, within in 30 minutes | ||||
Test room | High temperature exposure range | Ambient temperature +20 to +200°C | |||
Low temperature exposure range | –65 to -5°C | ||||
Recovery time | Within 15 minutes | ||||
Temperature fluctuation | ≤±0.5℃ | ||||
Temperature deviation | ≤±3℃ | ||||
Controller | Programmable color LCD touch screen controller | ||||
Cooling system | Mechanical compression refrigeration system | ||||
Refrigerating unit | French TECUMSEH compressor | ||||
Refrigerant | R404A, R23 | ||||
Air circulation | Centrifugal wind fan | ||||
Safety device | Over-temperature protection; over-current protection; Refrigerant high-pressure protection; Earth leakage protection; | ||||
Exterior material | Steel Plate with protective coating | ||||
Interior material | SUS304 stainless steel | ||||
Thermal insulation | Polyurethane foam | ||||
Observation window | Interior lighting | ||||
Standard configuration | 2 pieces of stainless steel shelves, Φ 50 round cable port | ||||
Power Supply | 380V 50HZ | ||||
Environmental conditional | 5℃~+40 ℃ ≤85% RH |
Description
LIB 3TS series thermal shock test chamber, it is just one chamber for test room, it circulates cold and hot air through the pneumatic damper on the left and right sides.This design makes external size smaller, and this 3TS series thermal shoc chamber are pre-heated and pre-cooled to achieve faster test temperature.
The test chamber can pre-record teh programs, so that customers can start test only click program numbers. Standard and custom models meet different requirements.
Features
The test specimens remain stationary and don’t moved
Pneumatic damper type thermal shock chamber
One test room configuration
Temperature recovery time less than 15 minutes
Programmable color LCD touch screen controller
Mechanical compression refrigeration system
Casters, shelf, and cable port are standard
Lamp inside of chamber
Ethernet and USB(option)
Large viewing window
Adjustable and removable sample shelves
Safety protection system
CE mark, ISO17025 calibration
Model | 3TS-210 | ||||
Internal dimensions(mm) | 500*500*400 | 700*600*500 | 700*780*550 | 900*800*700 | |
Overall dimensions(mm) | 1150*1950*2100 | 1350*2100*2200 | 1350*2250*2300 | 2500*2250*2150 | |
Sample Loads | 10kg | 15kg | 25kg | 35kg | |
Pre-heat room
| Upper limit preheat temperature | +220℃ | |||
Heating time | Ambient temperature to ~ + 200℃, within in 30 minutes. | ||||
Pre-cool room | Lower limit pre-cool temperature | -70℃ | |||
Cooling time | Ambient temperature to ~ -70℃, within in 30 minutes | ||||
Test room | High temperature exposure range | Ambient temperature +20 to +200°C | |||
Low temperature exposure range | –65 to -5°C | ||||
Recovery time | Within 15 minutes | ||||
Temperature fluctuation | ≤±0.5℃ | ||||
Temperature deviation | ≤±3℃ | ||||
Controller | Programmable color LCD touch screen controller | ||||
Cooling system | Mechanical compression refrigeration system | ||||
Refrigerating unit | French TECUMSEH compressor | ||||
Refrigerant | R404A, R23 | ||||
Air circulation | Centrifugal wind fan | ||||
Safety device | Over-temperature protection; over-current protection; Refrigerant high-pressure protection; Earth leakage protection; | ||||
Exterior material | Steel Plate with protective coating | ||||
Interior material | SUS304 stainless steel | ||||
Thermal insulation | Polyurethane foam | ||||
Observation window | Interior lighting | ||||
Standard configuration | 2 pieces of stainless steel shelves, Φ 50 round cable port | ||||
Power Supply | 380V 50HZ | ||||
Environmental conditional | 5℃~+40 ℃ ≤85% RH |
Description
LIB 3TS series thermal shock test chamber, it is just one chamber for test room, it circulates cold and hot air through the pneumatic damper on the left and right sides.This design makes external size smaller, and this 3TS series thermal shoc chamber are pre-heated and pre-cooled to achieve faster test temperature.
The test chamber can pre-record teh programs, so that customers can start test only click program numbers. Standard and custom models meet different requirements.
Features
The test specimens remain stationary and don’t moved
Pneumatic damper type thermal shock chamber
One test room configuration
Temperature recovery time less than 15 minutes
Programmable color LCD touch screen controller
Mechanical compression refrigeration system
Casters, shelf, and cable port are standard
Lamp inside of chamber
Ethernet and USB(option)
Large viewing window
Adjustable and removable sample shelves
Safety protection system
CE mark, ISO17025 calibration