+ 86 187 0087 5368     info@lib-industry.com 
LEAD PROVIDER OF ENVIRONMENTAL TEST CHAMBERS
DETAIL
You are here: Home » News » Technical Knowledge » What Are UV Aging Test

What Are UV Aging Test

Views: 227     Author: Site Editor     Publish Time: 2020-08-13      Origin: Site


What is the purpose of the light aging test?

Through accelerated tests that simulate the effects of long-term exposure to natural light, the results of the weather resistance of the materials are obtained.


The difference between a blackboard thermometer (BPT) and a black label thermometer (BST)

The main difference: The blackboard thermometer uses an insulated black metal plate base, while the black label thermometer is not used. Generally, the temperature of the black label thermometer is about 5°C higher than the temperature of the blackboard thermometer.

 

What is fluorescent ultraviolet lamp (UV lamp)?

A fluorescent lamp that emits at least 80% of the total output light energy of ultraviolet light below 400nm.



What are the types of UV lamps in the reliability laboratory?

There are two types of UV lamps: UVA-340, UVB-313EL


xenon aging and uv aging-2


What are the different uses of different types of UV lamps?

UVA-340: Simulate the ultraviolet part of sunlight, mainly used for light aging test of outdoor products.

UVB-313EL: It is widely used in fast and economical testing of durable materials. It will accelerate the aging of materials and sometimes lead to abnormal results. The customer's consent must be obtained when using it.

UVA-351: Used to simulate the ultraviolet part of sunlight passing through window glass, mainly used indoors.

 

Irradiance of laboratory UVA-340 lamp:

0.68W/m2@340nm is equivalent to the sunlight at noon in summer, and get fast results; 1.38W/m2@340nm is twice the maximum value of the sun to get fast results; 0.35W/m2@340nm is equivalent to the daylight in March/September, suitable for ordinary testing or testing with lower UV light intensity.


Irradiance of laboratory UVB-313 lamp:

0.67W/m2@340nm; 1.23W/m2@340nm Very fast test, applied to quality control or testing of materials with good durability; 0.48W/m2@340nm UVB-313 lamp performs long-term illumination when SAE J2020 standard is implemented.



What are the conditions for a complete UV test?

Should include: radiation intensity (irradiation), lamp type, non-illumination type (condensation and spray), temperature during illumination and non-illumination, time of illumination and non-illumination, total test time or test cycle frequency.


What are the commonly used UV test standards?

ASTM G154-2006 Non-metallic materials UV fluorescent lamp exposure

ISO 4892.3-2006 Plastic Laboratory Light Source Exposure Method Part 3: Fluorescent UV Lamp

GB/T 16422.3-1997 Plastic Laboratory Light Source Exposure Method Part 3: Fluorescent UV Lamp


What are the related test parameters of LIB UV ultraviolet aging machine?

Blackboard temperature: 30~80℃;

Irradiation intensity: 0.3~20W/m2 (340nm/313nm);

Sample board size: 75*150mm (48 sample boards in total)


Related Products

content is empty!

Please complete fields to get price quote and specifications today. LIB team will fast response.

ABOUT US

CONTACT US

Please complete fields to get price quote and specifications today. LIB team will fast response.